西门子QRC1系列火焰探测器-电眼 |
QRC1系列火焰探测器-电眼
品牌:SIEMENS(西门子)
产地:德国 |
产品介绍 |
Blue-flame detectors for the supervision of blue- or yellow-burning oil or gas flames. Blue-flame detectors are used primarily in connection with burner controls for burners of small capacity in intermittent operation.
-
The QRC1... is a compact UV-sensitive blue-flame detector with an integrated preamplifier.
-
It is designed for frontal and lateral (90°) illumination. This type of flame detector is suited for use with burner controls LOA2... (except LOA25...), LOA3..., LOA44..., LMOx4..., LGB3..., LAL1... and LAL4... and – in terms of plug-in facility – is compatible with the photoresistive detectors QRB1...
-
The spectral sensitivity of the QRC1... is a maximum of approximately 300 nm, which means that it optimally covers the range of UV radiation of blue-burning oil or gas flames. Since the QRC1... is also capable of detecting UV fractions of the radiation spectrum of other luminous sources (e.g. boiler house illumination or sunlight), the usual regulations for extraneous light still apply.
-
The QRC1... may not detect UV radiation of ignition sparks, as otherwise lockout will occur during the prepurge time, due to extraneous light. | |
技术参数 |
主要参数 |
主电压 |
AC230V -15/+10% |
主频率 |
50...60Hz ±6% |
功率 |
0.35VA |
火焰信号反应时间 |
300ms |
自带电缆长度 |
1m最大 |
辅助电缆长度 |
20m最大 |
保护等级 |
IP40 |
安全等级 |
II |
重量(带350mm线) |
29g | | |
环境条件 |
运输环境 |
IEC 60 721-3-2 |
内部条件 |
class 2K2 |
机械条件 |
class 2M2 |
温度范围 |
-20...+80ºC |
湿度 |
<95% |
运行环境 |
IEC 60 721-3-3 |
内部条件 |
class 3K5 |
机械条件 |
class 3M1 |
温度范围 |
-20...+60ºC(可短暂到75ºC) |
湿度 |
<95% |
不得进水 | | | |
|